MQ9 Carbon Monoxide, Combustible Gas Sensor Module

95,00 EGP

حساس (سينسور) يُستخدم في رصد وقياس الإشارات الفيزيائية لمشاريع Arduino و Raspberry Pi وإنترنت الأشياء. | a sensor module used to detect and measure physical signals for Arduino, Raspberry Pi, and IoT projects.

Description

MQ9 Carbon Monoxide, Combustible Gas Sensor Module

The MQ-9 Carbon Monoxide, Combustible Gas Sensor Module is designed for detecting carbon monoxide (CO) and combustible gases such as methane (CH₄), propane (C₃H₈), and liquefied petroleum gas (LPG). Utilizing a sensitive SnO₂ semiconductor material, the sensor exhibits lower conductivity in clean air and higher conductivity in the presence of target gases. It operates by cycling between high and low temperatures to detect different gases: low temperature (1.5V) for CO detection and high temperature (5.0V) for combustible gases. The module provides both analog and digital outputs, with an adjustable sensitivity via an onboard potentiometer, making it suitable for various gas detection applications.

Features
  • High sensitivity to carbon monoxide, methane, propane, and LPG.
  • Fast response time and stable performance.
  • Dual analog and digital output options.
  • Adjustable sensitivity through onboard potentiometer.
  • Simple drive circuit for easy integration.
  • Long operational life and low cost.
Specification
  • Parameter: Value
  • Operating Voltage: 5VDC
  • Heater Voltage (High): 5.0V±0.2V AC or DC
  • Heater Voltage (Low): 1.5V±0.1V AC or DC
  • Heater Resistance: 31Ω±3Ω
  • Heater Consumption: ≤350mW
  • Detection Range (CO): 10–1000ppm
  • Detection Range (CH₄/LPG): 100–10000ppm
  • Analog Output Voltage: 0–5V
  • Digital Output Voltage: 0V or 5V (TTL Logic)
  • Preheat Time: ≥24 hours
  • Operating Temperature: -10°C to 50°C
  • Operating Humidity: 20% to 90% RH
  • Dimensions: 32mm x 20mm
PINOUT
  • VCC power supply 5V
  • GND ground connection
  • AO – Analog output
  • DO – Digital Output
Applications
  • Domestic gas leakage detectors.
  • Industrial gas detection systems.
  • Portable gas detectors.
  • Smart home safety devices.
  • Environmental monitoring systems.

    Handling & Safety

    Always power the gas sensor within its rated voltage range and double-check pin connections before powering up. Avoid touching the circuit while it is live, and keep it away from moisture and static discharge during handling. These steps protect the part from damage.

    Why Choose This Gas Sensor

    First, it is a widely used part in the maker community, so documentation, libraries and example wiring diagrams are easy to find. Second, it works with common microcontroller platforms, so you can get it running quickly. Third, our team checks basic function before it ships. So, you avoid guesswork when you order. As a result, this is a dependable choice for learning, prototyping or finishing a project.

    Wiring Tips

    Before final assembly, test the part on a breadboard if you are unsure of the wiring. Therefore, you avoid damaging your main circuit during first power-up. Also, keep connections short and secure to reduce noise and reading errors. In addition, label each wire during assembly so future troubleshooting is easier. As a result, your project stays reliable and easy to maintain.

    Good to Know

    A well-matched gas sensor saves time on debugging later. Therefore, double-check the pin layout and voltage requirements against your other components before wiring everything together. Also, keep the original packaging until you have tested the part, since this makes any exchange easier if something is not right. In addition, bookmark the manufacturer’s documentation for quick reference during your build. As a result, your project moves forward with fewer surprises.

    وحدة مستشعر غاز أول أكسيد الكربون والغازات القابلة للاشتعال MQ9

    تم تصميم وحدة مستشعر MQ9 لاكتشاف أول أكسيد الكربون (CO) والغازات القابلة للاشتعال مثل الميثان (CH₄)، والبروبان (C₃H₈)، وغاز البترول المسال (LPG).
    يستخدم المستشعر مادة شبه موصلة حساسة من SnO₂، حيث تكون موصلية المستشعر منخفضة في الهواء النقي، وترتفع عند وجود الغازات المستهدفة.
    يعمل المستشعر عبر التبديل بين درجتي حرارة مختلفتين للكشف عن الغازات:

    • درجة حرارة منخفضة (1.5V) للكشف عن أول أكسيد الكربون.

    • درجة حرارة مرتفعة (5.0V) للكشف عن الغازات القابلة للاشتعال.

    توفر الوحدة خرجين تماثلي (Analog) ورقمي (Digital)، مع إمكانية تعديل الحساسية عبر المقاومة المتغيرة المدمجة، مما يجعلها مناسبة لمجموعة واسعة من تطبيقات كشف الغازات.


    المميزات

    • حساسية عالية لأكسيد الكربون والميثان والبروبان وغاز البترول المسال.

    • استجابة سريعة وأداء ثابت.

    • خرج تماثلي ورقمي مزدوج لتعدد الاستخدامات.

    • إمكانية ضبط الحساسية بسهولة من خلال المقاومة المتغيرة المدمجة.

    • دائرة تشغيل بسيطة وسهلة الدمج في المشاريع.

    • عمر تشغيلي طويل وتكلفة منخفضة.


    المواصفات التقنية

    • المعلمة: القيمة
    • جهد التشغيل: 5 فولت تيار مستمر
    • جهد السخان (مرتفع): 5.0V ±0.2V تيار متردد أو مستمر
    • جهد السخان (منخفض): 1.5V ±0.1V تيار متردد أو مستمر
    • مقاومة السخان: 31Ω ±3Ω
    • استهلاك السخان: ≤350mW
    • مدى الكشف (CO): 10–1000ppm
    • مدى الكشف (CH₄/LPG): 100–10000ppm
    • خرج تماثلي: 0–5V
    • خرج رقمي: 0V أو 5V (منطق TTL)
    • زمن التسخين المبدئي: ≥24 ساعة
    • درجة حرارة التشغيل: من -10°C إلى 50°C
    • رطوبة التشغيل: 20% إلى 90% RH
    • الأبعاد: 32مم × 20مم

    توزيع الأرجل (PINOUT)

    • VCC: مصدر الطاقة 5 فولت

    • GND: الأرضي

    • AO: الخرج التماثلي

    • DO: الخرج الرقمي


    التطبيقات

    • كاشفات تسرب الغاز المنزلية.

    • أنظمة الكشف الصناعي عن الغازات.

    • أجهزة الكشف المحمولة.

    • أنظمة الأمان الذكية للمنازل.

    • أنظمة مراقبة البيئة.

Looking for more sensors or modules? Browse our full range of sensors and modules for your next project.

Shipping & Delivery
Reviews (0)
0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “MQ9 Carbon Monoxide, Combustible Gas Sensor Module”

Your email address will not be published. Required fields are marked *

You have to be logged in to be able to add photos to your review.